2012/10/05

Multiple UPSes

OK, so now for a problem that probably only affects me. I have multiple UPSes in my server closet. A large one (APC BackUPS XS-1300 LCD) for most of the computers in the closet and a mid-sized one (APC BackUPS XS-900) for the computers in my office. I have a long wire running through the floor into my office. Why not put the mid-sized one in the office itself? Because it has a noisy fan.

Both these USPes are connected via USB to one computer. This computer assigns nearly randomly the device name, based on where I've plugged them into a USB hub. This resulted in the computers in the basement thinking they were on the 900 and my office thinking it was on the 1300. Not acceptable.

Using lsusb, I see the UPSes are at 2:5 and 2:4

# lsusb
Bus 004 Device 001: ID 0000:0000  
Bus 003 Device 001: ID 0000:0000  
Bus 005 Device 001: ID 0000:0000  
Bus 001 Device 001: ID 0000:0000  
Bus 002 Device 005: ID 051d:0002 American Power Conversion Uninterruptible Power Supply
Bus 002 Device 002: ID 05e3:0604 Genesys Logic, Inc. USB 1.1 Hub
Bus 002 Device 001: ID 0000:0000  
Bus 002 Device 004: ID 051d:0002 American Power Conversion Uninterruptible Power Supply

Again with lsusb, I can find the serial number:

# lsusb -v -s 2:5
Bus 002 Device 005: ID 051d:0002 American Power Conversion Uninterruptible Power Supp
ly
Device Descriptor:
  bLength                18
  bDescriptorType         1
  bcdUSB               1.10
  bDeviceClass            0 (Defined at Interface level)
  bDeviceSubClass         0
  bDeviceProtocol         0
  bMaxPacketSize0         8
  idVendor           0x051d American Power Conversion  
  idProduct          0x0002 Uninterruptible Power Supply
  bcdDevice            1.06
  iManufacturer           3 American Power Conversion
  iProduct                1 Back-UPS XS  900 FW:830.E8 .D USB FW:E8 
  iSerial                 2 BB0842016813  
... SNIP ...

Another way to get the same info:

# udevinfo -a -p /class/usb_device/usbdev2.5
  looking at device '/class/usb_device/usbdev2.5':
    KERNEL=="usbdev2.5"
    SUBSYSTEM=="usb_device"
    SYSFS{dev}=="189:132"

  looking at parent device '/devices/pci0000:00/0000:00:1d.0/usb2/2-1/2-1.3':
    ID=="2-1.3"
    BUS=="usb"
    DRIVER=="usb"
    SYSFS{configuration}==""
    SYSFS{serial}=="BB0842016813  "
    SYSFS{product}=="Back-UPS XS  900 FW:830.E8 .D USB FW:E8 "
    SYSFS{manufacturer}=="American Power Conversion"
    SYSFS{maxchild}=="0"
    SYSFS{version}==" 1.10"
... SNIP ...

Then I created some custom udev rules in /etc/udev/rules.d/99-apc.rules:

KERNEL=="hiddev*", SYSFS{serial}=="BB0842016813*", NAME="apc900"
KERNEL=="hiddev*", SYSFS{serial}=="JB0741003708*", NAME="apc1300"

I could also have used SYSFS{product} for matching, but the serial number uniquely defines these UPSes. I need the * for globbing because the serial number is padded with spaces, as can be seen in the udevinfo output.

Next reload the udev db:

# udevcontrol reload_rules
# udevtrigger
# ls -l /dev/apc*
crw------- 1 root root 180, 97 Oct  5 12:53 /dev/apc1300
crw------- 1 root root 180, 96 Oct  5 12:53 /dev/apc900

YAY!

2011/09/12

UPS and power conditioning

If you have a server or any computer that is important, it needs an UPS. Something large enough for 5-10 minutes of power outage. But it is not enough to just plug the power into the UPS. You must also plug into UPS data port. And set up the software that will allow the computer to detect the power outage and shutdown before the battery runs out.

This is non-negotiable.

Not doing this risks you showing up Monday morning and not getting any work down while an admin drives 100 km to fix a problem.

And if you have any piece of important electronic equipment, you'll want a filter. And no the fuse on your power bar doesn't count.